Product Overview
Moeller FAZ-C10/2 10A C-Curve 2-Pole DIN Rail Breaker
Condition
Used. Evaluation: Visual inspection only. Function testing not performed. Housing shows minor scuffs and surface wear from previous installation. Terminal screws intact and operational. Markings legible: xPole FAZ-C10/2, Icu=15kA, JR54E, 480Y/277 VAC, IEC 60898, with -F1 equipment marker attached.
Same or next business day shipping from our Idaho warehouse. Reliable parts since 1999. Honest pricing, no nonsense.
We are here for our customers, with a no-hassle satisfaction guarantee.
Product Overview
Engineered for branch and control circuit protection on standard 35 mm DIN rail, the Moeller FAZ-C10/2 provides dual-line thermal-magnetic interruption. Rated at 10 A with a Type C instantaneous trip characteristic, it shields machinery control panels, industrial automation systems, and branch power distribution networks against overloads and short circuits.
Key Features
- Current rating: 10 A continuous
- Number of poles: 2-pole
- Trip characteristic: Type C curve (5-10 In)
- Voltage rating: 480Y/277 VAC (UL/CSA), 240/415 VAC (IEC)
- Interrupting capacity: 10 kA at 480Y/277 VAC, 15 kA Icu per IEC 60947-2
- Mounting: 35 mm symmetrical DIN rail (EN 60715) with snap-in retention clip
- Terminals: Bi-connect screw clamp terminals with molded 12 mm wire strip guide
- Contact position indicator: Green/red status window under dual toggle levers
Applications
- Industrial control panel builds requiring 10 A branch circuit supplementary protection
- Safeguarding dual-line control transformer primaries and 208V/240V machinery feeds
- Retrofitting and repairing legacy automation cabinets and European-designed machinery
- Dedicated power bench supplies and custom workshop tool distribution racks
Frequently Asked Questions
What trip curve does this breaker use, and what is its typical trip response?
This unit features a Type C trip curve, calibrated to trip magnetically between 5 and 10 times its rated 10 A current. It handles standard inductive inrush loads like small motors, transformers, and control relays without nuisance tripping.
What mounting style does the FAZ-C10/2 use?
It mounts directly onto standard 35 mm DIN rail (EN 60715) and secures in place with a spring-loaded rear latching clip.
Are terminal screws and wire clamping plates included?
The captive terminal screws and internal pressure clamps are integral to the housing on both the line (terminals 1 and 3) and load (terminals 2 and 4) sides.
What should I expect regarding condition and previous service wear on this pulled unit?
This unit is pre-owned and shows light surface scuffing from previous panel mounting and wire termination. Toggle actions are firm and contact position indicators cycle smoothly. It is sold visually inspected and covered by our satisfaction guarantee.
Solid European DIN-rail hardware from the era when panel components were built to outlast the machines they guarded. Snap it onto your rail and give that dual-line feed the honest protection it needs.